Summary

Results-oriented, high-energy, hands-on professional, who employs strong organizational skills, leadership and thorough knowledge to achieve organization goals.

Skills
  • Strong Team Player
  • Critical Thinking
  • Time Management
  • Troubleshooting
  • Organizational Skills
  • Calculating tolerances
  • Equipment repairs
  • Device calibration
  • Self Motivated
Experience
Calibration Technician IV, 07/2017 to Current
Plug Power Inc.Adairsville, GA,
  • Perform investigations and initiation of any documentation resulting from out of tolerance conditions with respect to instrumentation and calibration standards.
  • Serve as CCMS System Administrator, as needed.
  • Procure quotes, initiate purchase requisitions, ship to vendor, receive back from service, review and approve vendor documentation and complete work orders.
  • Process Blue Mountain (CCMS) calibration work requests,change requests, asset inductions, asset creation, MDT creation and calibration event creation and equipment scheduling.
  • Installation, configuration, calibration and troubleshooting of 4-20 mA process loop instrumentation, including but not limited to; pressure transmitters, differential pressure transmitters used for flow and level measurements, pressure and temperature switches, temperature transmitters, gas/ liquid flow meters, (gravimetric and ultrasonic transducer), pharmaceutical instrumentation, like bioreactors, mixers, isolators, gas detectors, freezers, incubators, autoclaves, recorders, centrifuges, thermometers, process tanks, UV analyzers, scales (analytical up to floor scales), pH, conductivity, chromatography and filtration skids, etc..
  • Test control systems and assist in validation of new and existing manufacturing facilities.
  • Maintains critical metrology standards, equipment & tools.
  • Maintain all calibration records, work orders and investigations in an accurate manner in compliance with cGMP's by the utilization of the site CCMS and Document Management Systems.
  • Assists in SOP creation for instrumentation calibration.
  • Review/ approve completed calibration records for accuracy and completeness.
  • Serve as an SME to assist the Calibration Supervisor, Manager and Quality teams to resolve deviations and track closure of any associated corrective actions.
  • Experience using electronic calibration management systems such as Blue Mountain RAM and Delta V control system.
  • Serve in a lead role for Calibration Group.
  • Oversee calibration activities during supervisor's absence.
Sr. Instrumentation Technician, 01/2016 to 07/2017
EnscoCocoa Beach, FL,
  • Installation, configuration, calibration and troubleshooting of fieldbus and 4-20 mA process loop instrumentation, including but not limited to; pressure transmitters, differential pressure transmitters used for flow and level measurements, pressure and temperature switches, temperature transmitters, gas/ liquid flow meters, (gravimetric and ultrasonic transducer), pharmaceutical instrumentation, like gas detectors, isolators,freezers, incubators, T.O.C, autoclaves, recorders, centrifuges, thermometers, process tanks, UV analyzers, scales (analytical up to floor scales), pH, conductivity, chlorine, turbidity, D.O, ozone, chromatography skids, CIP/ SIP systems, etc..
  • Proficient with Lock-Out/Tag-Out (LOTO), Delta V, Blue Mountain RAM and JDE.
  • Provide technical training to co-workers and new staff.
  • Present strong mathematical knowledge and various math applications.
  • Set up and perform test activities.
Instrumentation Technician II, 01/2013 to 04/2015
Abbvie, IncJohnson City, TN,
  • In house calibration of laboratory equipment, including but not limited to, electronics, temperature, humidity, physical/ dimensional, pressure, mass, from class F up to class 1 through ABA 5 run method, USP scale calibration, pipettes, through Pipette Tracker software, mass flow meters and controllers through Fluke's Molbloc system, water analysis equipment, such as pH, conductivity, chlorine, turbidity, etc..
  • Installation, configuration, calibration and troubleshooting of 4-20 mA process loop instrumentation in water treatment plants, including but not limited to; pressure transmitters, differential pressure transmitters used for flow and level measurements, pressure and temperature switches, temperature transmitters, flow meters, (gravimetric and ultrasonic transducer), REES monitoring system calibration, manufacturing and pharmaceutical instrumentation, like gas detectors, freezers, CO2 incubators, autoclaves, ovens, recorders, centrifuges, thermometers, process tanks, scales (analytical up to floor scales), pH, conductivity, chlorine, turbidity, chromatography skids, etc...
  • Provide technical training to co-workers and new staff.
Instrumentation Technician, 01/2008 to 01/2011
Tomas Cuerda Inc.City, STATE,
  • Installation, calibration and maintenance of Hach water analysis equipment, such as pH, conductivity, turbidity meters, chlorine analyzers, spectrophotometers.
  • Process Instrumentation, pressure, flow, level, temperature transmitters.
  • Laboratory equipment, mass calibration from class F up to class 1.
  • Gas flow meters, DC/ Low Frequency, torque, physical/ dimensional, temperature, humidity, scales.
  • Provide on site calibration for various pharmaceutical companies.
Education and Training
Associate of Science: Instrumentation, Expected in 2007
San Juan University College - San Juan, PR,
GPA:
Certifications
  • Member of I.S.A (International Society of Automation), various online courses completed.

By clicking Build Your Own Now, you agree to our Terms of Use and Privacy Policy

Disclaimer
Resumes, and other information uploaded or provided by the user, are considered User Content governed by our Terms & Conditions. As such, it is not owned by us, and it is the user who retains ownership over such content.

How this resume score could be improved?

Many factors go into creating a strong resume. Here are a few tweaks that could improve the score of this resume:

87Good

Resume Strength

  • Formatting
  • Length
  • Personalization
  • Strong Summary
  • Target Job

Resume Overview

School Attended
  • San Juan University College
Job Titles Held:
  • Calibration Technician IV
  • Sr. Instrumentation Technician
  • Instrumentation Technician II
  • Instrumentation Technician
Degrees
  • Associate of Science