Knowledgeable installation and inspection technician who understands inspection, repair processes, how they are carried out and methods to increase efficiency. Self-driven to complete tasks and motivated to reach and exceed set goals. An individual that is dedicated to continuing education and advancing in the field of fire protection and life safety. A fire protection specialist dedicated to continuous process improvement in the face of rapidly evolving and changing markets.
|
|
Project management, program author and testing/commissioning of Honeywell XLS panels and Vesda systems. Project management consist of monitoring multiple installation company's progress and performance meeting NFPA guidelines. Generate the fire alarm program based off drawings, NFPA requirements and matrix requests while deploying panel programming based off the progress of the project. Adapt the program to change orders or customer request and assist with troubleshooting discrepancies. Tested and commissioned all fire alarm installations per NFPA 72 and providing all close-out documentation to the AHJ upon completion. Achieved XLS3000 fire alarm programmer's certification. Achieved Vesda programmer's certification and software deployment. On schedule to receive Honeywell BDA & fiber DAS training certification. One of my most significant projects to date was co-writing the fire alarm program, testing and commissioning the Amazon Air Hub located in Hebron, KY.
Inspection and maintenance of fire alarm systems consisting of addressable, mass notification and conventional panels. Inspection and maintenance of wet, dry, antifreeze, deluge and pre-action systems. Developed the standard operating procedure for fire alarm inspections for tablet based. Lead inspector for jobs consisting over 1200 devices and managing 2-6 inspectors per project. Provided training and hands on for tablet based invoicing system. Develop and train new fire service technicians per standard operating procedures and review company guidelines. Achieved fire service technician captain level. Obtained Kentucky fire alarm and sprinkler license within one year. I also obtained Ohio fire alarm, sprinkler and extinguisher license within one year.
Analyzed weekly and monthly financial statements to track branch progress. Review and provide management of the sprinkler inspection and installation department, fire alarm inspections and hood and extinguisher department. Managed sub-contracting consisting of hood cleaning. Reviewed and submitted billing to accounts receivable. Provided and managed alarm monitoring, consisting of new account information, billing cycle, and renewals. Reviewed inspections reports to perform follow up on impairments and quotes. Met deadlines by proactively managing individuals and team tasks. Developed a client re-occurring program for kitchen hood inspections, pre-engineered inspections, fire alarm inspections, sprinkler inspections, fire extinguisher inspections and monitoring to track customers based on monthly, quarterly, semiannual and annual inspections. Provided customer follow ups for service based off daily monitoring reports. Obtained South Carolina fire extinguisher license. Considered a working manager and provided labor to all departments when needed while performing my daily duties.
Inspection, installation and maintenance of fire alarm systems consisting of addressable and conventional panels. Inspection and maintenance of wet, dry, antifreeze, pre-action and deluge systems. Installation and restocking of first aid kits consisting of commercial,restaurant and customer specific. Completed an apprenticeship program for all aspects of hood grease removal. Performed national account inspections in a timely manner. Provided quotes for extinguisher, emergency light and fire alarm inspections. Designed and implemented a fire alarm inspection report and standard. Special hazard inspector for Vanderbilt medical center. Inspections consisted of providing weekly, monthly, quarterly, semiannual and annual inspections on twenty five pre-action and deluge valves. The system hazards consisted of medical equipment, heliports, data rooms, and elevator shafts. Successfully completed the Tennessee alarm qualifying agent examination.
Inspection, installation and maintenance of fire alarm systems consisting of addressable, mass notification and conventional panels. Inspection and maintenance of wet and dry sprinkler systems. Installation, maintenance, recharge, low pressure hydrostatic test and high pressure hydrostatic test on all fire extinguishers. Installed high pressure hydrostatic testing equipment and obtained Department of Certification to perform. Obtained Kentucky Fire alarm and sprinkler inspector license. Lead inspector for Fort Knox military base performing fire alarm semi-annual and annual inspections. Performed inspections at the military base for three years, managed and scheduled for five inspectors.